Search:tensile test machine universal test machine  ozone test chamber
Product
Contact us

Dongguan Company

Add: Xinhe Management of 

area, Wanjiang District, 

Dongguan city, Guangdong

 province, China

Tel: +86 769 23388229

Fax: +86 769 23388227

Mobile phone:

       Homlin :  +86 135 5970 0919


       Leon      : +86 136 8898 5187

Email:sales2@hengzhunx.com

            sales1@hengzhunx.com


Dongguan Tianan Office

Rm. 1117, Building A1, Tianan 

Cyber Park, No. 1, Huangjin Road,

 Nancheng District, Dongguan, 

Guangdong, China (Mainland)

Tel: +86 769 23388225

Fax: +86 769 23388227

Mobile phone:

Connie: +86 137 1188 8650

Shelly:+86 136 8898 4470



       Shanghai Company


       Add: Building B 4-3, No.398, 

Jinglian Road, Minhang District,

Shanghai

Tel: 021-54399880-15

Fax: 021-64549471-12

Email:sales1@hengzhunx.com




HZ-4020 High Voltage Cable Test Machine
    High voltage cable test machine suitable for measuring the compressive strength performance, it can be intuitive, accurate, fast and reliable test of the breakdown voltage of the measured object, leakage current electrical safety performance indicators, the withstand voltage tester product range is in accordance with the GBIEC, CSA, UL, JIS and other standards requirements designed withstand voltage output AC0-15kV, breakdown current AC0-20MA. Suitable for a variety of household appliances, power switch, wire and cable, transformers, terminals, high-pressure bakelite electrical motor, medical, chemical, instrumentation, security and strong power system voltage, insulation resistance, leakage current test, is also research laboratories, technical supervision departments indispensable test equipment.

Detailed:

High voltage cable test machine suitable for measuring the compressive strength performance, 

it can be intuitive, accurate, fast and reliable test of the breakdown voltage of the measured object, leakage 

current electrical safety performance indicators, the withstand voltage tester product range is in accordance 

with the GBIEC, CSA, UL, JIS and other standards requirements designed withstand voltage output AC0-15kV, 

breakdown current AC0-20MA. Suitable for a variety of household appliances, power switch, wire and cable, 

transformers, terminals, high-pressure bakelite electrical motor, medical, chemical, instrumentation, security and

strong power system voltage, insulation resistance, leakage current test, is also research laboratories, technical

supervision departments indispensable test equipment.

  • Technical Parameter
  • Feature / Function
  • Standard
  • Main parts
  • Software / Controller

Technical parameter:

1.Input voltage 220V,50Hz  5A

2.Output voltage 0-15KV

3.Leakage current 0.5,1.0,1.5,2.0,3.0,5.0,10.0 ,20mA

4.Test time 0-99.99(S\M\H)

5.Volume 600*500*1300mm

6.Weight 40kg

 

QC Preliminaries knowledge

A.basic knowledge  Read the instruction .

B.Prepare work:

  ♦Power requirements of the scope of work 220V±10%VAC

  ♦ Fuse rating 250V/5A

  ♦ When the test machine work it has thousands of volts, it must have a reliable ground wire.

  ♦ The operator should be at the foot pad high voltage insulation pads, gloves insulated gloves.        

C.Instrument prohibited area deposited in the following conditions:

  ♦ Inflammable and explosive air environment.

  ♦ Unstable countertops.

  ♦ Direct sunlight place

  ♦ Damp places

  ♦ Corrosive air environment

  ♦ Dust air pollution.


Operating instructions:

1.Testing machine access with ground wire AC 220V 50Hz power

2.Open the power switch

3.Operate steps

A.Open at the high voltage   B.Close at the high voltage

A)Open at the high voltage test time:

♦ Turn on the instrument panel when high voltage test time/ turn off in the open gear.

♦ set up the testing time

♦ set up the leakage current gear

♦ Access to the high-voltage output test products.

♦ Press high-voltage key to start, the rotation high voltage adjustment knob to the desired voltage value.

♦Began high-pressure test, the arrival time of a qualified instrument high voltage reset (zero); super drain the instrument high voltage alarm.

B)Turn off at high voltage test time:

♦ Turn on the instrument panel when high voltage test time/ turn off in the open gear.

♦ set up the testing time

♦ set up the leakage current gear

♦ Access to the high-voltage output test products.

♦ Press high-voltage key to start, the rotation high voltage adjustment knob to the desired voltage value.

♦Began high-pressure test, the arrival time of a qualified instrument high voltage reset (zero); super drain the instrument high voltage alarm.

 

Repair and maintenance

1.Note placed environment must be kept clean, and don't wet

2.Necessary migration, please note that handling, do not damage and parts

3.Replace fixture must be pay attention to pick-and-place, in order to avoid the drop, bruising parts

4.Please apply for inspection regularly correction, in order to ensure the accuracy of the fuselage

5.Instrument panel parts, appearance often is brushed try, keep clean


Meet the standard :

GB,IEC,CSA,JIS,UL