Search:tensile test machine universal test machine  ozone test chamber
Product
Contact us

Dongguan Company

Add: Xinhe Management of 

area, Wanjiang District, 

Dongguan city, Guangdong

 province, China

Tel: +86 769 23388229

Fax: +86 769 23388227

Mobile phone:

       Homlin :  +86 135 5970 0919


       Leon      : +86 136 8898 5187

Email:sales2@hengzhunx.com

            sales1@hengzhunx.com


Dongguan Tianan Office

Rm. 1117, Building A1, Tianan 

Cyber Park, No. 1, Huangjin Road,

 Nancheng District, Dongguan, 

Guangdong, China (Mainland)

Tel: +86 769 23388225

Fax: +86 769 23388227

Mobile phone:

Connie: +86 137 1188 8650

Shelly:+86 136 8898 4470



       Shanghai Company


       Add: Building B 4-3, No.398, 

Jinglian Road, Minhang District,

Shanghai

Tel: 021-54399880-15

Fax: 021-64549471-12

Email:sales1@hengzhunx.com




HZ-2914 Automatic fire lighting detector
    Automatic fire lighting detector is our new laboratory equipment with reference to the national standard GB17945-2010 "fire emergency lighting and evacuation systems" developed. The machine of three parts: the computer control center, electrical performance test cabinets, optical performance tester. By computer control technology, will focus on the complex simplicity of the experimental procedure, reducing the time involved in manually. Powerful PLC controller, can be multiple sets of electrical performance tests simultaneously, and the experimental accuracy than manual measurement accuracy. The machine can be used to detect the national standard GB17945-2010 "fire emergency lighting and evacuation system," as stipulated in its own power type fire emergency lighting and fire emergency lights.

Detailed:

Product Summary:

Automatic fire lighting detector is our new laboratory equipment with reference to the national standard 

GB17945-2010 "fire emergency lighting and evacuation systems" developed. 

The machine of three parts: the computer control center, electrical performance test cabinets, optical 

performance tester. By computer control technology, will focus on the complex simplicity of the experimental 

procedure, reducing the time involved in manually. Powerful PLC controller, can be multiple sets of electrical 

performance tests simultaneously, and the experimental accuracy than manual measurement accuracy. 

The machine can be used to detect the national standard GB17945-2010 "fire emergency lighting and 

evacuation system," as stipulated in its own power type fire emergency lighting and fire emergency lights.

  • Technical Parameter
  • Feature / Function
  • Standard
  • Main parts
  • Software / Controller
NO. Test items (GB17945-2010 requirements)

Requirements (lighting needs 

to meet the requirements)

Manual inspection before the experiment, appearance inspection, etc.


The lamp is the main power working 

condition, check the manual self-test function;

Then make lamps in emergency status, 

checking off emergency control function.

The system should be done 

manually self-test function

The first experiment: Electric automatic test process project

1

7.5 voltage fluctuation experiments 

Laboratory equipment 

Experimental equipment should meet 

the following conditions: 

  1. Output voltage: 100V ~ 250V 
  2. continuously adjustable within; 

b) AC frequency is 50Hz. 

7.5.3 Step 

Adjusting experimental apparatus were 

the main power supply voltage is 242V 

and the sample 187V, check the status

 of their work.

6.7 system in the range of 85% to 110% 

of the mains voltage, the state of 

emergency should not be transferred.

 (187V ~ 242V)

2

7.6 Conversion voltage experiments 

Experimental equipment should meet the 

following conditions: 

  1. Output voltage: 100V ~ 250V 
  2. continuously adjustable within; 

b) Frequency: 50Hz. 

7.6.3 Experimental Procedure 

The main power cable according to the 

wiring diagram of the sample test access means,

 it is in the main power state, adjusting

 the experimental apparatus, the output 

voltage is gradually decreased until the

 sample is transferred to an emergency 

state, the recording output voltage; then

 the output voltage slowly rise until the 

sample back to the main power status,

 record the output voltage; regulation 

mains voltage lamps to make changes 

slowly, observe and record the state of

 the lamp in the mains voltage range of

 60% to 85%.

6.8 mains voltage from the main 

power system state into a state of 

emergency when the mains voltage 

should be in the range of 60% to 85% 

within. Reply mains voltage main power 

from the emergency state to state should

 not exceed 85% of the mains voltage;

 when the system voltage at any voltage

 in the mains voltage 60% to 85% 

range, status indicators, and should not 

occur repeatedly beating the relay 

switching phenomena such as non-shiny 

style light source flicker state should 

not occur.

3

7.2.2 24h charging into the state of 

emergency lighting, fluorescent light fixtures to 

check the starter to start the case (if necessary 

Hui Kai can be short-circuited), and record

the conversion time and start time, until the 

battery voltage reaches its termination 

recorded emergency work time.

System response time of conversion 

should not exceed 5s; emergency 

conversion time systems using high-risk

 areas should not exceed 0.25s. 

The emergency response system time 

should not be less than 90min, and not

less than the nominal emergency

lighting itself working hours

4

7.2.2.5 comes off the main power supply 

type or picture-type lamps, it is in a state 

of emergency, which was the main power 

supply lines are shorted to ground work,

 checking fixtures

Own power-and picture-type lamps 

state of emergency should not be

 subject to its short circuit, grounding 

the main power supply line.

5

7.3.2.2 The sample was transferred to the

 state of emergency until the over-

discharge protection starts at the end 

of this instantaneous measurement of the 

battery voltage, and observe whether the 

sample is restarted, and then measuring 

the static discharge current.

Type should have its own power 

supply over-discharge protection. 

Battery discharge voltage of not less

than 80% of rated voltage battery,

static discharge current should not 

be greater than 10-5C20A.

The second class of experiments:Electrical individually controlled experimental projects

6

7.4 Repeat conversion experiments 

7.4.2 Experimental Procedure 

50 consecutive times to sample the main 

power status remains 1min, then transferred 

to the state of emergency to keep 20s.

The system should be able to complete 

at least 50 times in a row, "the main 

power status 1min → state of emergency

 20s → main power status 1 min" 

working state cycle.

7

7.2.2.13 so shiny style state of emergency

 lights, measure its shining light and 

non-light frequency and time ratio.

Frequency shiny shiny style marker

lamps shall be (1 ± 10%) Hz, lighting

and non-lighting time ratio should be 4:1.

8

7.3 Charge and discharge test 

7.3.2.1 The sample discharge end of the main 

power is turned on, check the state of 

charge indicator, 24h after measuring the 

charging current. To make maintenance-

free lead-acid batteries for emergency

 lighting luminaires centralized power, 

battery charging current to be measured 

during charging.

6.4.2.1 charging time should not exceed 24h
9

7.7.2 charge and discharge durability test 

10 consecutive times to fully charge the sample 

into the state of emergency until after 

discharge protection starts. The first record, 

the last time the discharge

10 6.9 system should be completed 

"full charge and discharge termination

 → → full charge" charge cycle, the 

discharge process. The last time 

should not be less than 85% of the 

discharge initial discharge time, and 

meet the requirements of 6.3.2.

The third experiment:Optical separate pilot project

10

7.2.2.3 

1, the main power state to the next state 

of emergency immediately different lights

 (including lighting lights mark part) were 

measured according to the following steps 

surface brightness; 

2, immediately after discharge 80min different 

lights (including lighting lights mark part) 

were measured according to the following 

steps surface brightness: 

  1. For the only green or red graphics, text 
  2. information constitutes logo lights on its 
  3. graphics, text, select 10:00 
  4. uniformity measurements; 

b) For constituted by a combination of color 

graphics, text, information signs as a symbol 

of light, according to Appendix B of the access 

point mode, on its graphics, text, select 

10:00 uniformity measurements, then the

 corresponding points on adjacent another 

color select the 10:00 measurements. 

c) instructions for duplex lights, should a)

 or b), respectively measuring the surface

 brightness of the two surfaces.

Fire Emergency lighting surface brightness 

should meet the following requirements: 

  1. constitute only a green or red graphic
  2.  logo lights, which mark the surface of
  3.  not less than the minimum brightness
  4.  50cd/m2, should not exceed the maximum

 brightness of 300 cd/m2; 

b) or a combination of green and 

white combination of red and white 

pattern constituting the surface of the lamp 

as a symbol mark of not less than

 the minimum brightness 5cd/m2, should 

not exceed the maximum brightness

 300cd/m2, white, green or red its maximum

 brightness and minimum brightness The 

ratio should not exceed 10. Green or 

red white and brightness corresponding 

points on both sides of the junction 

adjacent ratio of not less than five and

 not more than 15.

11

7.2.2.4 

1, the main power state to the next state 

of emergency measure immediately 

lighting (including lighting lights illuminated 

part of) the flux; 

2, measured immediately after discharge 

80min lighting (including lighting lights 

illuminated part of) the state of flux at the 

time of emergency and evacuation flashlights 

glowing color temperature.

Fire emergency lighting flux state 

of emergency should not be less than

 its nominal flux, and not less than 50lm.